Single-Phase Mining Dry-Type Transformers | KKDG | Hongmei
Single-Phase Mining Dry-Type Transformers: KKDG
If your non-coal mine runs single-phase auxiliary loads, we supply custom KKDG single-phase mining dry-type transformers built to order for your site voltage and power.
- Certified example: KKDG-50/0.693(0.4), 50 kVA, 0.693(0.4) kV, KY non-coal, IP22
- Built nameplates: 1, 3, and 5 kVA single-phase units at 50–60 Hz
- Minimum order starts at 1 unit, with no sample-making fee
- Custom build lead-time guidance is 7–15 days, packed in wood cases or cartons
- Remote video and online guidance with a one-year warranty from receipt
Choosing between single-phase and three-phase power for your auxiliary load? Read Single-Phase or Three-Phase for Mining Auxiliary Loads? first. If your mine needs three-phase capacity, check our three-phase KKSG mining options, or browse our full Transformer Product Range.
KKDG Single-Phase Units Built with 1, 3, and 5 kVA Nameplates
Our built KKDG single-phase units show you what our factory nameplates carry across 1, 3, and 5 kVA builds. Each nameplate lists 50–60 Hz and an I/I winding arrangement (single-phase primary and single-phase secondary windings), with Zhejiang Hongmei Electrical Manufacturing Co., Ltd. printed as the manufacturer.
| Built unit model | Rated capacity | Input voltage field | Output voltage field | Printed certificate number |
|---|---|---|---|---|
| KKDG-1KVA | 1 kVA | 220 V | 36 V | CMExC24.1858 |
| KKDG-3KVA | 3 kVA | 380 V | 36 V | CMExC24.1858 |
| KKDG-5KVA | 5 kVA | 660 V 380 V | 220 V 36 V | CMExC24.1858 |
Use these three past builds as nameplate references while we quote your own configuration. On the KKDG-5KVA nameplate, 660 V 380 V and 220 V 36 V sit side by side with no stated pairing or capacity split between outputs. Each of these nameplates carries the certificate number CMExC24.1858; the certificate itself covers the models it lists. For any new order, we’ll review your exact supply voltage, auxiliary load voltage, and required kVA before quoting.
How to Size a KKDG Single-Phase Transformer for Auxiliary Loads
Single-phase transformer apparent power equals steady-state RMS (effective AC) load voltage multiplied by load current, divided by 1,000: kVA = V × I ÷ 1000. With your auxiliary circuit voltage and full-load current from panel labels or equipment nameplates, you can calculate load kVA before requesting a quote. To check full-load current for a candidate kVA rating at your secondary voltage, reverse the formula to I = kVA × 1000 ÷ V.
When an auxiliary equipment nameplate lists real power in kW instead of apparent power in kVA, you still need apparent power to size the transformer. Since real power equals apparent power multiplied by power factor (P = S × power factor), convert kW using kVA = kW ÷ power factor. Inductive loads also draw reactive power, and both the transformer and distribution feeder must carry total apparent power. A lower power factor raises required kVA and current for the same real work, so sizing directly from kW can understate the load.
Two quick example calculations show how to apply these formulas to your own load list. For a single-phase 220 V steady-state load drawing 20 A, apparent power is 220 × 20 ÷ 1000 = 4.4 kVA. If an equipment nameplate instead lists 3.6 kW at a 0.8 power factor, apparent power is 3.6 ÷ 0.8 = 4.5 kVA. You can substitute the actual voltages, currents, or kW values from your own load schedule into the same two equations. That gives you a steady-state load baseline while we confirm the final rating during quotation.
Motor loads draw extra inrush current during startup beyond steady-state running amps. If your auxiliary circuit feeds pumps, fans, or other motor loads, you can check starting demand separately in our guide to transformer sizing for running and motor-starting loads. For full single-phase and three-phase calculations, our kVA to amps worked examples walk through both formulas.
CMExC24.1858 Certificate Scope, KY Mark, IP22 Rating, and ISO Systems
Mining certificate CMExC24.1858 shows a single-phase KKDG transformer we built under KY certification for non-coal mine sites. Here, KY is the mark on China’s certificate for general-type mining electrical apparatus used in non-hazardous areas, issued under GB/T 12173-2008. Under IEC 60529, IP22 defines two levels of enclosure protection. The first digit (2) protects against solid foreign objects larger than 12.5 mm in diameter and finger access to live parts. The second digit (2) protects against dripping water when the enclosure is tilted up to 15°. Even so, CMExC24.1858 limits use to chambers and main roadways free of dripping water or dust ingress, and to non-coal mining sites. Locations with dripping water or dust fall outside these certificate conditions, so describe your operating site in your enquiry and we’ll review it with you.
| Certificate field | Entry on CMExC24.1858 |
|---|---|
| Product name | Mining general-purpose single-phase dry-type transformer |
| Listed model | KKDG-50/0.693(0.4) |
| Rated specification | 50 kVA, 0.693(0.4) kV |
| Mark and standard | KY; GB/T 12173-2008 |
| Protection and site scope | IP22; chambers and main roadways without dripping water or dust ingress, and non-coal mining sites |
| Certificate holder and manufacturer | Zhejiang Hongmei Electrical Manufacturing Co., Ltd. |
| Printed certificate dates | 2024-12-03 to 2029-12-02 |
KKDG-50/0.693(0.4) serves as a certified build example and does not automatically cover other custom ratings. If your custom single-phase unit requires a KY certificate, note that in your enquiry so we can check coverage against your exact model and site conditions. Alongside mining product records, we hold ISO 9001, ISO 14001, and ISO 45001 management system certifications whose qualified scope includes the production and sales of single-phase dry-type transformers. These are company management system certifications, while product certificates, ISO certificate numbers, and validity dates appear under KKDG document examples.
Grey KKDG Enclosure Layout for Site Access and Wiring

Use this factory enclosure photo to see the side handles, blue sockets, and top nameplate layout before you finalise housing dimensions. Because unit rating, enclosure size, housing material, and enclosure layout follow your order, confirming installation access early helps you specify the housing.
Wood or Carton Packing with a One-Year Warranty from Receipt
We pack single-phase KKDG transformers in wood cases or cartons based on your order. You can see how we prepare units for shipment and discuss transformer packing before dispatch with our team.
We provide a one-year warranty counted from the day you receive the goods. Whenever your engineers have installation or operating questions, our team supports you through remote video calls and online guidance.
Five Inputs to Prepare Before Requesting a KKDG Quote
Pull these five details from your load list and panel labels so we can review your single-phase KKDG configuration accurately:
- Input and output voltages: The mine panel supply voltage and the single-phase voltage your auxiliary equipment requires.
- Required power rating: Your auxiliary load in kVA or kW (include power factor if your load list only gives kW).
- Enclosure dimensions and material: Any space limits, footprint constraints, cable-entry side, or housing material your site requires.
- Installation environment: Confirmation of a non-coal chamber or main roadway, plus whether dripping water or dust is present.
- Mining certificate needs: Whether your project requires a KY certificate so coverage can be checked for your exact build.
Frequently Asked Questions on KKDG Single-Phase Mining Transformers
Six practical answers cover KKDG single-phase site limits, certification scope, phase choice, warranty start dates, order minimums, and packing before you request a quote.
Can a KKDG single-phase transformer be used in a coal mine or explosive atmosphere?
No. Mining certificate CMExC24.1858 covers general-type apparatus under GB/T 12173-2008 strictly for non-coal mine chambers and main roadways free from dripping water and dust ingress. Coal mines and explosive atmospheres fall outside this certificate’s scope. If you’re unsure how your site is classified, share your operating environment so we can confirm whether KKDG fits.
Does a custom KKDG single-phase order come with a KY certificate?
Certificate CMExC24.1858 lists KKDG-50/0.693(0.4) as a certified example, and coverage applies strictly to the models explicitly listed on it. Note any KY certificate requirement alongside your rating and site conditions so coverage can be reviewed before production.
Should I specify a single-phase KKDG transformer or a three-phase KKSG transformer?
Your phase choice depends on your auxiliary equipment and the supply voltage at your mine panel. If you’re still weighing both setups, our single-phase vs. three-phase mining guide compares load types and wiring. When your site runs three-phase motors or distribution feeders, our three-phase KKSG mining transformers cover three-phase demand.
When does the one-year warranty start, and how do you handle technical support?
Your one-year warranty starts on the day you receive the transformer, not the day it leaves our factory. If your maintenance crew runs into installation or operating questions, we walk your team through checks via remote video calls and online guidance.
What is the minimum order quantity, and is there a sample-making fee?
You can place an order starting from a single custom unit, which makes it practical to order a trial build or a one-off spare. We charge no separate sample-making fee on top of custom unit orders, with each build quoted per specification.
How are KKDG single-phase transformers packed before shipment?
Based on your order, we pack KKDG single-phase transformers in wood cases or cartons. If your site or forwarder needs to align on wood-case or carton handling and dispatch prep, you can review our packing and dispatch preparation page ahead of shipment.